Technologies: ON/OFF
Application:
This product is suitable for engineering projects, outdoor lighting buildings, hotels, shopping malls, and other decorative lighting purposes.
Product Specifications
P/N | LED Quantity | CCT(K) | CRI | LEDs/m | LUMENS (lm/m) | Vf. (V.) | Current (mA/M) | Power (W/M) | Cut Length (MM) | Max Run (M) |
RL-FV2416024283520-830-FWD2721 | 2835 | 2700 | 80/90 | 24 | 1500 | 24 | 833 | 20 | 41.67 | 5 |
3000 | 1600 | |||||||||
4000 | 1700 | |||||||||
6500 | 1700 |
Other Specifications
Protection grade | IP67 |
Working temperature(°C) | -25~+60 |
Storage environment temperature (°C) | -25~+70 |
Standard length | 5 |
Maximum cascade length(m) | 5 |
weight | / |
Remark
The test environment temperature is 25±2°C;
The above data are typical values, the actual parameters of the product may be different from the typical data; the data is subject to change without notice;
The above "/" means that this parameter is not required for the time being.
Applied Standards
CE ROHS cULus LISTED ETL Intertek CB Reach UKCA
Common product faults and their troubleshooting methods
Fault Phenomena | Possible Causes | Troubleshooting Methods |
All lights off | 1. Mains power failure | Power on |
2. Open circuit or short circuit at switching power supplyoutput triggering auto-protection | Troubleshoot and restore power | |
3. Reverse polarity at LED strip power input | Check wire connection status to ensure correct polarity | |
Partial lights off | 1. Partial switching power supply failure | Inspect power supply system and resolve faults |
2. Wiring error in partial LED strip circuits | ||
3. Reverse polarity in partial LED strips | Correct wiring | |
LED uneven brightnessor insufficient brightness | 1. Power supply overload | Replace with higher-power supply according to load |
2. Excessive line loss in switching power circuits orsignificant line loss discrepancies | Maintain LED strip operating voltage within +5% of rated voltage 1. Shorten power cable length between power supply and LEDstrip or use larger gauge wires; 2. Ensure number of LED strips per circuit ≤ max allowed cascadingquantity and keep cascading quantities similar per circuit). | |
3. Excessive serial connection of LED strips | Adjust LED strip quantity per power branch to meet maxallowed cascading requirements per circuit | |
LED flickering | 1. Poor contact at connection points | Identify and resolve poor contact points |
2. Switching power supply malfunction | Replace switching power supply |
- If the external flexible cable of this product is damaged, the cable must be replaced by the manufacturer or similarly qualified personnel to prevent hazards.
- For specific installation arrangements and precautions, refer to the product user manual.
- Data in this specification is based on standard products, Actual delivered products may vary, subject to physical measurements.
- All product diagrams in this specifcation are schematic diagrams, Actual delivered products may differ, subject to physical obiects