Features:
Technologies: ON/OFF, RGBW
Application:
This product is suitable for engineering projects, park lighting, buildingshotels, shopping malls, home, display shelves, indirect lighting,dark slot lighting, outline, decorative lighting and other purposes.
Product Description
P/N | LED | CCT(K) | CRI | LEDs/m | Lumens | Vf. (v.) | Current | Power | Cut | Max Run |
(lm/m) | (mA/m) | (W/m) | Length | |||||||
RL-FV2412140283512-830-FWS1020 | 2835 | 2700K | 80/90 | 140 | 280 | 24V | 500 | 12 | 50mm | 5m |
3000K | 280 | |||||||||
4000K | 300 | |||||||||
5700K | 300 | |||||||||
RL-FV2412096505012-RGBW-FWS1020 | 5050 | R:620-625nm | 80 | 96 | 17 | 24V | 500 | 12 | 62.5mm | 5m |
G:520-530nm | 42 | |||||||||
B:465-467nm | 9 | |||||||||
W:2700-6500K | 9 |
Other Specifications
Protection grade | IP67 |
Working temperature(°C) | -25~+60 |
Storage environment temperature (°C) | -25~+70 |
Standard length | 5 |
Maximum cascade length(m) | 5 |
weight | / |
Remark
The test environment temperature is 25±2°C;
The above data are typical values, the actual parameters of the product may be different from the typical data; the data is subject to change without notice;
The above "/" means that this parameter is not required for the time being.
Common product faults and their troubleshooting methods
Fault Phenomena | Possible Causes | Troubleshooting Methods |
All lights off | 1.Mains power failure | Power on |
2.0pen circuit or short circuit at switching power supplyoutput triggering auto-protection | Troubleshoot and restore power | |
3.Reverse polarity at LED strip power input | Check wire connection status to ensure correct polarity | |
Partial lights off | 1.Partial switching power supply failure | Inspect power supply system and resolve faults |
2.Wiring error in partial LED strip circuits | ||
3.Reverse polarity in partial LED strips | Correct wiring | |
LED uneven brightnessor insufficient brightness | 1.Power supply overload | Replace with higher-power supply according to load |
2.Excessive line loss in switching power circuits orsignificant line loss discrepancies | Maintain LED strip operating voltage within +5% of rated voltage 1. Shorten power cable length between power supply and LEDstrip or use larger gauge wires; 2. Ensure number of LED strips per circuit ≤ max allowed cascadingquantity and keep cascading quantities similar per circuit). | |
3.Excessive serial connection of LED strips | Adjust LED strip quantity per power branch to meet maxallowed cascading requirements per circuit | |
LED flickering | 1.Poor contact at connection points | Identify and resolve poor contact points |
2.Switching power supply malfunction | Replace switching power supply |
- If the external flexible cable of this product is damaged, the cable must be replaced by the manufacturer or similarly qualified personnel to prevent hazards.
- For specific installation arrangements and precautions, refer to the product user manual.
- Data in this specification is based on standard products, Actual delivered products may vary, subject to physical measurements.
- All product diagrams in this specifcation are schematic diagrams, Actual delivered products may differ, subject to physical obiects
- Technical modifications may be implemented without prior notice.
- Shenzhen Meishang Lighting Co., Ltd. reserves the final interpretation rights of this manual.